Air Chucks are used to inflate and deflate tires of cars, trucks, buses, and agricultural or OTR vehicles. It provides several models for different applications, from long chucks with retention to short chucks with holders. They are easy to use and ensure no leaks when inflating tires on. Tire Air Chuck,Half Zinc Tire Air Chuck,Half Cooper Tire Air Chuck Ningbo Heyu Tire Repairs Co., Ltd. , https://www.auto-repair-tool.com
Welcome to our factory in Shanghai
Ranges: Chiller, Water Chiller, Air Cooled Chiller, Water Cooling Chiller, Air Cooled Chiller, Heat Pump, Ari cooled heat pump
As an industrial water chiller, this air cooled screw heat pump chiller has the following features:
1. Cooling capacity: 90kw~760kw
2. Cooling conditions: Chilled water inlet temperature is 12 degrees, outlet temperature is 7 degrees. Ambient temperature is 35 degrees
Heating conditions: Outside the air-dry-bulb temperature is 7 degrees, wet bulb temperature is 6 degrees, hot water outlet temperature is 45 degrees
3. Input power: 3P-380V-50Hz, Allowable fluctuate voltage: ± 10%, allowable voltage difference in phase: ± 2%.
4. Measuring noise spot: 2m ahead and 1.5m high in front of chiller with average measurement on four dimensions.
5. Semi-closed 5: 6 asymmetric twin-screw compressor from world-renowned brand, trouble-free operation over 100000hours.
6. Four stages volume control or 0%-100% automatic regulation.
7. Fluoride-resistant high-performance motor from French.
8. Use PLC microcomputer control from Germany Siemens LCD touch screen, both English and Chinese human-machine interface.
9. Wide range of variable chilled water temperature to meet the industrial requirements throughout whole year.
10. Friendly choose to use environmentally R407C or R134A refrigerant.
11. Free step-down triangle stars starter
Air cooled heat pump, heat pump
Air Cooled Screw (Heat Pump) Chiller (Single compressor)
Item                                      Type
DLA-(H)
901
1301
1601
2001
2551
3101
3501
4101
4301
4901
5251
5701
6151
6901
7351
7601
Nominal cooling capacityKW
90
130
160
200
255
310
350
410
430
490
525
570
615
690
735
760
104Kcal/h
7.7Â
11.2Â
13.8Â
17.2Â
21.9Â
26.7Â
30.1Â
35.3Â
37.0Â
42.1Â
45.1Â
49.0Â
52.9Â
59.3Â
63.2Â
65.3Â
RT
26Â
37Â
46Â
57Â
73Â
88Â
100Â
117Â
122Â
139Â
149Â
162Â
175Â
196Â
209Â
216Â
Nominal heating capacity
KW
100
145
180
225
285
350
395
460
484
550
590
640
690
775
830
855
104Kcal/h
8.6Â
12.5Â
15.5Â
19.3Â
24.5Â
30.1Â
34.0Â
39.6Â
41.6Â
47.3Â
50.7Â
55.0Â
59.3Â
66.6Â
71.4Â
73.5Â
RT
28Â
41Â
51Â
64Â
81Â
100Â
112Â
131Â
138Â
156Â
168Â
182Â
196Â
220Â
236Â
243Â
Run control
Use PLC microcomputer control
Power Supply
380V/ 3N /50Hz
Machine power
kW
30.2
43.2
51.3
63.4
76.3
96.3
109.6
128.9
133.6
150.4
164.3
178.2
188.3
216.5
229.6
238.8
Machine operating current
A
52.9
75.6
89.8
111
133.5
168.5
191.8
225.6
234
263
288
312
330
379
402
418
CompressorType
Semi-closed 5:6 asymmetric twin-screw compressor
 Startup type
Y Start
Â
Refrigeration  power
kW
27.5
39.6
47.7
58.2
71.1
91.1
99.3
118.6
123.3
140.1
150.5
164.4
174.5
199.3
212.4
218.2
Refrigeration current
A
48.1
69.3
83.5
101.9
124.4
159.4
173.8
207.6
216
245
263
288
305
349
372
382
Heating powerÂ
kW
26.8
38.6
46.5
56.7
69.3
88.8
96.8
115.6
120.2
136.6
146.7
160.3
170.1
194.3
207.1
212.7
Heating current
A
46.9
67.6
81.4
99.2
121.3
155.4
169.4
202.3
210
239
257
281
298
340
362
372
EvaporatorType
Pipe dry high efficiency heat exchanger
 Flow
m3/h
15.4Â
22.3Â
27.4Â
34.3Â
43.7Â
53.1Â
60.0Â
70.3Â
73.7Â
84.0Â
90.0Â
97.7Â
105.4Â
118.3Â
126.0Â
130.3Â
Interface size
DN
65
65
80
80
100
100
100
125
125
125
125
150
150
150
150
150
Water pressure drop
kPa
44
45
47
49
50
50
52
55
57
59
63
65
67
72
74
75
Condenser
Type
 Imported efficiency copper pipe and aluminum foil wing heat exchanger
Air flow
m3/h
34970Â
50476Â
61815Â
76845Â
97054Â
119375Â
133720Â
157321Â
164673Â
187530Â
201042Â
218571Â
234970Â
264673Â
281964Â
291131Â
Condenser fan
QuantityÂ
SETÂ
6
8
8
3
3
4
4
6
6
8
8
8
8
10
10
12
Stand-alone powerÂ
kW
0.46
0.71
0.71
1.6
2.2
2.2
2.2
1.4
1.4
1.6
2.2
2.2
2.2
2.2
2.2
2.2
Refrigerant
 Type
R22
Refrigerant volume
kg
23
33
41
51
65
79
90
105
110
125
134
146
157
177
188
194
Overall size
 Length
mm
2450
2750
2950
3550
3550
3550
3550
4600
5000
5600
6350
6700
6900
7200
7500
8500
 Width
mm
1350
1350
1400
1400
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
 Height
mm
2020
2020
2200
2200
2300
2560
2560
2560
2560
2560
2560
2560
2560
2560
2560
2560
Noise
dB(A)
63
63
63
64
64
66
66
67
67
67
68
68
68
69
69
69
Machine weight
kg
1850
2000
2400
2600
2800
3300
3550
3750
3950
4400
4600
5100
5500
5750
5900
6250
Operating weight
kg
2000
2200
2600
2900
3100
3600
3900
4100
4300
4800
5100
5600
6100
6300
6500
6900
Air Cooled Chiller with High Quality
Model NO.: DLA-S2-500A
Application Fields: Electroplating
Application Machine: Precision Machine Tool
Certification: ISO, CE
Condition: New
Size(mm): 3600*2160*2690
Weight(Kg): 5200
Trademark: DARREN
Transport Package: Standard Wooden Package
Specification: CE, SGS, ISO9001
Origin: China
HS Code: 8418692090
Heat Pump, Air Cooled Heat Pump